Judging by CT analysis, we decided implant the 23 mm sized Edwards SAPIEN 3 with norminal volume. Under monitored anesthesia control, 6 Fr sheath and temporary pacemaker were inserted through left femoral vein, and 7 Fr sheath and 6 Fr pig-tail catheter were inserted through left femoral artery. After both peripheral angiograms with pig-tail catheter, we checked proper a puncture site of right femoral artery. 8 Fr sheath was inserted through right femoral artery, and then one 8 Fr Proglide devices were placed into the right femoral artery. After removal of the sheath, right femoral artery was dilatated and 14 Fr Edwards E-sheath was inserted. An AL 1 diagnostic catheter with a 0.035 inch Amplatz stiff wire was used to cross the aortic valve. Aortic root angiography was done. Under fluoroscopy control, a 23-mm Edwards SAPIEN 3 prosthesis crimped on the delivery catheter (NovaFlex Delivery System) was placed at the best position of the aortic annulus, half and half at the annulus level, and was successfully deployed by inflating the balloon under rapid ventricular pacing ( Movie 1). After valve implantation, final fluoroscopy showed trivial aortic regurgitation. ( Movie 2). Then After the intervention, puncture site was sutured by prepared Proglides.
|